Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Int. braz. j. urol ; 49(4): 501-510, July-Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1506396

ABSTRACT

ABSTRACT Objective: To describe the technique of transurethral harvesting of bladder mucosal graft using the Holmium:YAG (Ho-YAG) laser and describe the preliminary results from 7 cases where this graft was used for urethroplasty. Materials and Methods: We performed a single-stage dorsal onlay urethroplasty using bladder mucosal graft in 7 patients with anterior urethral stricture. Transurethral harvesting was performed with the Ho-YAG laser. We performed a prospective and descriptive analysis with uroflowmetry performed at 30, 90 and 180 days after surgery and applied the PROM translated into Portuguese before and 6 months after urethroplasty. Results: Seven patients were included, 2 (28.5%) with penile urethral stricture, and 5 (71.5%) with bulbar urethral stricture. Mean stricture length was 50mm (range 35-60mm). Stricture etiology was trauma in 3 (42.9%) patients, iatrogenic in 1 (14.3%) patient, and idiopathic in 3 (42.9%) patients. Two patients (28.6%) had previously undergone ventral buccal mucosa urethroplasty. Mean bladder mucosal graft length was 52.86mm (± 13.801), and mean harvest time was 46.43min (± 14.639). Dorsal onlay urethroplasty using bladder mucosa was successfully completed in 5 patients (71.4%). Two patients (28.6%) couldn't have the procedure completed using bladder mucosa, one due to thermal damage of the graft during harvesting, and one due to insufficient graft length. In both cases the procedure was completed using buccal mucosa. Two patients (28.6%) experienced minor hematuria between the twelfth and eighteenth postoperative day, but neither required hospitalization and/or additional procedures. All patients achieved normalization of peak flow, and this was maintained throughout the follow-up period. Mean peak flow was 17.8 ml/s (± 3.271) at 30 days, 20.6 ml/s (± 5.413) at 90 days, and 19.6 ml/s (± 8.019) 180 days. Mean IPSS score decreased from 19.3 to 5.4. Similar improvements were also seen in the ICIQ-MLUTS Score (a mean drop from 3.8 to 2.0) and Peeling's Voiding Picture Score (a mean drop from 4.0 to 2.2). Quality of Life improved post urethroplasty, with increases in EQ-5D (from 0.6371 to 0.7285) and EQ-VAS (from 58.0 to 84.0). Conclusion: Transurethral harvesting of bladder mucosa using the Holmium laser (Ho-YAG) is feasible and reproducible. Our preliminary experience suggests that bladder mucosa grafts achieve comparable results to other grafts when used for dorsal onlay urethroplasty. Further research is needed to confirm these results.

2.
Radiol. bras ; 55(4): 242-252, Aug. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1394561

ABSTRACT

Abstract In recent years, the development of new imaging techniques and scoring systems have improved the diagnosis and management of small renal masses. Imaging-based nephrometry scoring systems play an interesting role in the planning of nephron-sparing surgery, providing surgeons with the information necessary to determine the complexity of the renal mass, to deliver the appropriate postoperative care, and to predict adverse outcomes. The aim of this study was to review nephrometry scoring systems, evaluating their characteristics and the relationships among them. The urology and radiology communities should decide which nephrometry scoring system will prevail and be used in daily practice.


Resumo O diagnóstico e o manejo das pequenas massas renais têm sido aprimorados nos últimos anos com o desenvolvimento de técnicas de imagem e escores que desempenham papel interessante no planejamento da nefrectomia parcial, fornecendo informações importantes ao cirurgião para determinar o tipo de tratamento em relação a complexidade da massa renal, cuidados pós-operatórios e previsão de complicações após as cirurgias. O objetivo deste estudo é revisar os escores de nefrometria, suas características e relações entre eles no cenário da cirurgia. Os serviços de urologia e radiologia devem decidir qual é o melhor escore de nefrometria para ser utilizado na prática diária.

3.
Int. braz. j. urol ; 48(1): 110-119, Jan.-Feb. 2022. tab, graf
Article in English | LILACS | ID: biblio-1356276

ABSTRACT

ABSTRACT Introduction: Nephrometric scores play an interesting role in nephron sparring surgery (NSS) planning. The aim of this study is to evaluate if R.E.N.A.L. score (RS) is capable to predict the occurrence of adverse events in laparoscopic NSS. Materials and Methods: We prospectively studied 150 laparoscopic NSS between 2015 and 2018 to evaluate the relationship between RS and incidence of adverse events. Clavien 3 or superior complications, warm ischemia time (WIT) over 30 minutes, tumor violation, positive surgical margins (PSM) and necessity of amplification of renal parenchyma during the resection of the masses to obtain free margins were considered as adverse events. We compared each item of the RS isolated and divided the patients between low risk and high risk. Results: Adverse results occurred in 48 cases (32%). Amplification of the margin of resection was observed in 28 cases (19%). WIT exceeded 30 minutes in 9 cases (6.1%), complications Clavien 3 or superior occurred in 13 cases (9%) and PSM were detected en 6 cases (4%). Comparing the patients with adverse outcomes and each item of the RS we did not find any statistical difference, but when divided into high risk and low risk, we found that patients in the high risk group had a higher tendency to present ad-verse results - 25.84% vs. 44.26% (p=0.03). Conclusions: RS system is a good way to predict adverse outcomes in NSS, especially in cases over 7. Further studies should focus on robotic approach and patient's characteristics other than the masses' aspects.


Subject(s)
Humans , Laparoscopy , Kidney Neoplasms/surgery , Retrospective Studies , Treatment Outcome , Nephrectomy/adverse effects , Nephrons/surgery
4.
J. pediatr. (Rio J.) ; 83(5): 441-446, Sept.-Oct. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-467355

ABSTRACT

OBJETIVO: Classicamente, o pênis tem duas funções: permitir a fertilização interna e direcionar o jato miccional. Entretanto, alterações objetivas do tamanho peniano podem levar ao diagnóstico de doenças. Além disso, é motivo comum de consulta médica a busca por parâmetros de normalidade do tamanho do pênis. Contudo, a antropometria do pênis da criança e do adolescente brasileiros ainda não foi devidamente estudada. O objetivo do estudo é realizar a antropometria do pênis de crianças e adolescentes brasileiros, estabelecendo referências para aplicação clínica. MÉTODOS: Foi realizado um estudo transversal, envolvendo 2.010 pacientes com idades variando entre 0 e 18 anos. Foram obtidas cinco medidas penianas: diâmetro da haste peniana; comprimento aparente e real do pênis flácido; comprimento aparente e real (CRTmax) do pênis flácido sob tração máxima. O desenvolvimento puberal foi caracterizado pelos critérios de Tanner. RESULTADOS: De todas as medidas penianas, o CRTmax foi a única que não apresentou variação significativa interpesquisador em todas as faixas etárias analisadas (p = 0,255). Os resultados foram distribuídos em tabelas com a média do CRTmax e os valores do que se considera micropênis (média - 2,5 desvio padrão) de acordo com as diferentes faixas etárias e com os diferentes graus de maturação sexual de Tanner. Foi desenvolvido um gráfico com a distribuição dos valores do CRTmax distribuído por percentis 10, 25, 50, 75 e 90 por faixa etária. CONCLUSÕES: De todas as medidas antropométricas penianas, o CRTmax é a única clinicamente útil. Recomendamos nossos resultados como referência de antropometria peniana para crianças e adolescentes brasileiros.


OBJECTIVE: Classically, the penis has two functions: to make internal fertilization possible and to direct the urine stream. However, objective abnormalities in penis size can lead to diseases being diagnosed. Furthermore, many medical consultations are the result of patients seeking parameters for normal penis size. Additionally, the penile anthropometry of Brazilian children and adolescents has not yet been properly studied. The objective of this study is to carry out penile anthropometry of Brazilian children and adolescents, establishing references for clinical use. METHODS: A cross-sectional study was carried out of 2,010 patients with ages varying from 0 to 18 years. Five penile measurements were taken: diameter of penile shaft; apparent and real length of flaccid penis; apparent and real (RSLmax) length of flaccid penis fully stretched. Pubertal development was defined according to Tanner's criteria. RESULTS: Only RSLmax, out of all of the penile measurements, did not exhibit significant interobserver variation at all ages analyzed (p = 0.255). Results were tabulated with mean RSLmax and the values that define micropenis (mean - 2.5 standard deviations) by age and by Tanner sexual maturity stages. A graph was plotted of the distribution of RSLmax results by the 10th, 25th, 50th, 75th and 90th percentiles and by age. CONCLUSIONS: Out of all of the penile anthropometric measurements, only RSLmax is clinically useful. We recommend our results as a reference standard for penile anthropometry of Brazilian children and adolescents.


Subject(s)
Adolescent , Child , Child, Preschool , Humans , Infant , Infant, Newborn , Male , Penis/anatomy & histology , Brazil , Cross-Sectional Studies , Observer Variation , Penis/growth & development , Reference Values , Sexual Maturation
SELECTION OF CITATIONS
SEARCH DETAIL